Immunity Testing
The inverse of emissions testing, immunity testing subjects a product to various RF phenomena to see if it affects the product's performance. If you have considered marketing your device internationally, you know that European Union member countries require immunity testing for products sold within their borders. We are capable of performing a full spectrum of immunity tests to guide you through this critical series of tests, significantly reducing your time to market.
We conduct electrostatic discharge (ESD), electrically fast transient (EFT), surge and power line disturbances. Our Semi-Anechoic Test chamber is capable of testing products from 26 MHz to 3 GHz and is designed with an oversized test volume to allow us to test products up to three meters in length in a single pass. If your product has a vulnerability, we can find it and help you fix it.
Immunity Site Specifications And Capabilities
Information
- Designed to handle CE Mark and other emerging immunity requirements
- A semi-anechoic chamber 8.6 m (L) x 5.5 m (W) x 3.4 m (H)
- An RF Immunity Test Chamber designed to handle oversized products and extended frequency ranges
- Single and three-phase Haefely Trench Electrical Fast Transient and Surge Test equipment
- Multiple test cells allowing more than one product to be tested at a time
- Automated test processes
- Ample space for setup, tear down, or modifications
- Comfortable client facilities so you can get some work done while your product is being tested
Features
- Products up 9.5 feet (L) x 5 feet (W) x 9.5 feet (H)
- Frequency range of 26 MHz to 3 GHz
- A calibrated Uniform Field Area of 3.0 meters x 1.5 meters (at the center of the turntable and at the front edge of the turntable)
Test Specifications
- EN 50082-1 Generic Immunity Light Industry
- EN 50082-2 Generic Immunity Heavy Industry
- EN 60601-1-2 (IEC 601-1-2) Medical
- IEC 801-2 ESD IEC 1000-4-2 ESD
- IEC 801-3 Radiated Susceptibility, 26 - 500 MHz
- IEC 1000-4-3 Radiated Susceptibility, 80 - 2000 MHz
- ENV 50204 Radiated Susceptibility, 900 MHz, Pulse Modulation
- ENV 50140 Radiated Susceptibility, 80 - 1000 MHz
- IEC 801-4 Electrical Fast Transients
- IEC 1000-4-4 Electrical Fast Transients
- IEC 1000-4-5 Surge Testing
- IEC 1000-4-6 Conducted Disturbance
- ENV 50141 Conducted Disturbance
- IEC 1000-4-8 Magnetic Field Susceptibility
- IEC 1000-4-11 Voltage Sag and Interruptions
Test Equiptment
- ESD, EFT, Surge, Magnetics - Haefely Trench
- RF Immunity - Lehman Chambers, Amplifier Research, Fisher Custom
- Communications - Hewlett Packard
- Flicker and Harmonics - Haefely Trench
Turntable
- Three meter EMCO turntable with an 8,800 pound payload, flush mount
Power
- Commercial service: 120/220 VAC, 200 amps, single phase, 60 Hz
- Site generator: configurable from 100-480 VAC, 125 amps/phase maximum, 50/60 Hz
- Programmable source: 0-250 VAC, 10 amps, single phase, DC to 400 Hz
- Additional power configurations available upon request
Debug and Rework Facilities
- Test equipment: HP 8591, near field probes and current clamps
- Comprehensive component library
- On-site stock of shielding materials and common EMI related components (i.e., filters, resistors, caps, inductors, etc.)
- Complete complement of hand tools and soldering equipment
- Complete soldering and de-soldering station with surface mount and through-hole capability
- ESD compliant