Emissions Testing
Domestic and international standards require both a conducted emission test (a measurement of the noise found on the power mains connected to a product) and a radiated emission test (a measurement of the RF signals generated and emitted by a product). Our site provides 3-, 10- and 30-meter testing in an all-weather facility that can handle products up to 13 feet long, 4 feet wide and 10 feet tall, and weighing up to 13,000 pounds. A preliminary radiated emission test on your product can be done in our Semi-Anechoic Test Chamber, allowing radiated emission test time to be reduced by as much as 50 percent.
Emission Site Specifications And Capabilities
General Information
- Designed to ANSI C63.7 with ellipses defined for a 30 meter range
- Obstruction Free Area: Major axis = 60 m, minor axis = 52 m
- Ground plane: 39 m x 18.3 m
- All weather enclosure: 18.3 m x 9.1 m
- Measurement distances: 3 m, 10 m, and 30 m
- Prescan capabilities in our semi-anechoic chamber
Test Specifications
- FCC Part 15 - Radio Frequency Devices
- FCC Part 15 - DoC Processes
- FCC Part 18 - Industrial Scientific Medical (ISM)
- EN55011 (CISPR-11) ISM
- EN55013 (CiSPR-13) Home Broadcast Receivers & Similar Equipment
- EN55014 (CISPR-14) Household Appliances
- EN55015 (CISPR-15) Lighting & Similar Equipment
- EN55022 (CISPR-22) Information Technology Equipment (ITE)
- ENSO081-1 Generic Emissions Residential, Commercial, and Light Industry
- ENS0081-2 Generic Emissions Heavy Industry
- EN60555-2 (IEC 555-2) Power Harmonics - Home
- EN60555-3 (IEC 555-3) Voltage Fluctuations - Home
- EN61000-3-2 Power Harmonics - ITE
- EN61000-3-3 Voltage Fluctuations - ITE
- ANSI C63.5
- Industry Canada RSS-210
Listings and Accreditations
- NVLAP accredited
- VCCI accredited
- BSMI accredited
- Listed with the FCC
- Listed with Industry Canada
Test Equipment (9 kHz to 40 GHz)
- Receivers: Rhode/Schwarz ESVS 30 and ESHS 30
- Spectrum analyzer: HP 8566B
- Antennas: EMCO Biconical 3108, EMCO Log 3146, EMCO Horn 3115, MIT-12A18, MIT-12A26, EMCO 6502 Magnetic Loop, Chase Bilog BL6111
- L1SN: Rhode/Schwarz ESH.2-Z5
Turntable
- Four meter diameter, 13,000 lbs. payload, flush mount
Shield Room
- 20'x 12'x 10' (Rayproof)
Lift
- 2000 lbs. capacity, 4.5' x 9' platform
Power
- Commercial service: 120/220 VAC, 200 amps, single phase, 60 Hz
- Site generator: configurable from 100-480 VAC, 125 amps/phase maximum, 50/60 Hz
- Programmable source: 0-250 VAC, 10 amps, single phase, DC to 400Hz
- Additional power configurations available upon request
Debug and Rework Facilities
- Test equipment: HP 8591, near field probes and current clamps
- Comprehensive component library
- On-site stock of shielding materials and common EMI related components (i.e., filters, resistors, caps, inductors, etc.)
- Complete soldering and de-soldering station with surface mount and through-hole capability
- ESD compliant